AdBlue Tank Failures: Fast Repair and Replacement – Reparlab
AdBlue tanks are critical components for the environmental compliance of modern diesel vehicles. At Reparlab by Faurecia Clarion, we turn the management of these complex failures into a reliable, fast, and long‑lasting solution thanks to our repair expertise.
| Fault code | Fault code description | Symptoms | Areas to check |
|---|---|---|---|
| P20E8 00 | Urea fluid pressure too low | Fluid leakage / odors (diesel, oil…) Exhaust smoke Knocking / banging / cracking Buzzing / crackling / ticking | Urea level‑pump module Heated urea line Urea injector Urea solution (AdBlue) Electrical wiring harness |
| P20E9 00 | Urea fluid pressure: upward deviation | Exhaust smoke Buzzing / crackling / ticking Fluid leakage / odors | Urea level‑pump module Urea injector |
| P3052 00 | Urea fluid pressure too low | Exhaust smoke Buzzing / crackling / ticking Knocking / banging / cracking Fluid leakage / odors | Urea injector Urea level‑pump module Electrical wiring harness Heated urea line Connectors Urea solution (AdBlue) |
| P3053 00 | Urea fluid pressure too high | Exhaust smoke Buzzing / crackling / ticking Fluid leakage / odors | Urea injector Urea level‑pump module Heated urea line Electrical wiring harness Connector |
| P3054 00 | Urea fluid pressure too high | Exhaust smoke Buzzing / crackling / ticking Fluid leakage / odors | Urea injector Urea level‑pump module Heated urea line Electrical wiring harness Connector |
The Reparlab by Faurecia Clarion offering
We now offer two options to meet your needs:
- Repair: Ship your faulty tank, which is inspected, cleaned, and made reliable by our technicians.
- Express Standard Exchange: For a selected range of references, receive a reconditioned product within 24 hours.
To benefit from this fast turnaround, select the “Exchange” option at step 3 of your order. A deposit is applied to the order and refunded within 7 days after receipt and inspection of your faulty part.